Recent content by R Weiland

  1. R

    Powering pixels both directions

    Typically we inject to avoid excessive voltage drop in the pixel wiring. If using multiple power supplies then yes you might need to separate the V+ lines. If powering a run of pixels from a single supply then powering the pixels from both ends is the standard practice. See the 101 Lighting...
  2. R

    is my config correct

    Just keep in mind that by running 600 nodes off a single port if you get a node failure depending where its at you could loose all the following nodes or half your tree at the worst.
  3. R

    Hello

    Hi Everyone, I am a retired Electrical Engineer, I reside in the USA, Seattle Washington area. I have been using LOR and AC lighting for about twelve years and I am in the process of migrating to Pixels and XLIGHTS. However, I will still use a couple of the LOR controllers on DMX to light up...